The Complete La Marina Villa Owner FAQ & Guide Costa Blanca

Moisture, Cracks & Structural Movement.

Why this damage occurs — genuine structural causes

1. Moisture (Water Ingress)

Moisture in La Marina is caused by:

Missing or inadequate waterproofing in 1990s construction

Capillary water absorption through unimpregnated masonry

Hydrostatic pressure in terraces and pool areas

Insufficient drying times in new buildings (very common today)

Salt pollution of the Costa Blanca → salt attracts water

Missing vapor barriers in interiors

Cracks in the exterior plaster → water penetrates and remains in the masonry

Incorrect tile installation (no drainage system, no flexible adhesive and no or to smal joints)

2. Hairline Cracks

Cracks are caused by:

Temperature fluctuations (Costa Blanca: 5°C at night → 35°C during the day)

Concrete shrinkage

Subsoil settlement (La Marina has many filled plots)

Inadequate reinforcement in old buildings

Rigid tiles on a shifting substrate

Moisture in the masonry → volume changes → cracks

New buildings completed too quickly → concrete doesn't dry properly

3. Structural Movement

Movement is caused by:

Soil settlement (sand + clay = unstable)

Insufficient foundation depth in 1990s villas

Poor subsoil compaction

Weak ring beams → walls move against each other

Vibrations from pool pumps / road traffic

Moisture under terraces → screed lifts or sinks

How to solve these problems professionally

1. Diagnosing the Moisture Source

Moisture must first be clearly located before any repairs are worthwhile.

Check capillary moisture using CM measurement.

Inspect exterior plaster for microcracks.

Open a small section to measure masonry moisture.

Check terraces for hollow areas (tapping test).

Identify water pathways by efflorescence.

2. Properly Stop the Moisture

The cause is eliminated, not just cosmetically covered.

Remove exterior plaster and apply a flexible, two-component waterproofing membrane.

Re-seale terraces with a drainage system and flexible adhesive class C2TE S1.

Protect interior walls with waterproofing plaster and a vapor barrier.

For new buildings: Observe drying times (concrete: minimum 28 days).

3. Correctly Repair Cracks

Cracks must be treated according to their cause, not just filled.

Hairline cracks: Elastic crack sealant

Movement cracks: Crack injection with epoxy resin

Facade cracks: Reinforcing mesh + mineral plaster

Tile cracks: Replacement + flexible adhesive class S1/S2

4. Stabilize structural movement

Movement must be stopped before new damage occurs.

Check foundation, underpin if necessary

Reinforce or replace ring beam

Rebuild terraces with compacted subgrade

Install expansion joints (every 4–6 meters)

Decouple pool surround to reduce vibrations

5. Long-term prevention

After the repair, the building is optimized for the Costa Blanca climate.

Protect exterior facade with hydrophobic impregnation

Construct terraces with drainage + flexible waterproofing

Keep interiors stable with dehumidifiers

Regularly check pool and equipment

Annual visual inspection of the facade

Leaking Roofs and Terraces

How to Repair Roofs and Terraces Professionally (Real Solutions)

1. Complete Removal of the Old Bitumen Membrane

The old waterproofing must be completely removed because:

Bitumen cannot be reworked

The new waterproofing will not adhere otherwise

Voids will remain

Moisture will be trapped

This is the only correct way.

2. Check and Rebuild the Screed (If Necessary)

If the screed:

Sounds hollow

Is damp

Has cracks

Is coming loose

→ It must be partially or completely replaced.

3. Professional Waterproofing Systems (proven since 1997)

Here are the systems that work most reliably in La Marina:

A) 2-Component Liquid Waterproofing (Polyurethane / PU)

This is the best solution for:

Flat roofs

Terraces

Roof terraces

Balconies

Advantages:

100% waterproof

Elastic (ideal for heat)

UV-resistant

Crack-bridging

Seamless

Adheres to concrete, screed, and tiles

B) Cementitious Waterproofing (2-Component Flexible Sealant)

Ideal for:

Terraces under tiles

Pool surrounds

Damp screeds

Advantages:

Vapor-permeable

Flexible

Ideal for the Costa Blanca climate

Compatible with tile adhesive

C) EPDM Membrane (rare, but very effective)

For large Roofs:

Extremely durable

UV-resistant

Seamless

Ideal for new builds

4. Decoupling mats (e.g., Schlüter-DITRA)

These mats:

Prevent cracking

Decouple tiles from the substrate

Drain moisture

Significantly increase the lifespan of the terrace

In La Marina, they are mandatory when laying tiles on terraces.

5. New tiles with flexible adhesive (C2TES1/S2)

Why?

Flexible adhesives absorb movement

Prevent detachment

Reduce cracking

Are water-resistant

Outdated Electrical and Plumbing Installations

Why electrical installations from the 1990s are dangerous today

1. Undersized wiring (1.5 mm² instead of 2.5 mm²)

Many villas were fitted with 1.5 mm² wiring for electrical outlets.

That was common practice back then—today it's no longer permitted.

Why?

Modern appliances draw more power.

Air conditioners, heaters, and pool pumps put a strain on the wiring.

1.5 mm² overheats more quickly.

Insulation becomes brittle → risk of short circuits.

Fire risk increases significantly.

The following are now standard sizes:

2.5 mm² for sockets

4–6 mm² for air conditioners

6–10 mm² for instantaneous water heaters

separate circuits for pool equipment

2. Old fuse boxes without residual current device (RCD) protection

Many houses have:

old screw-in fuses

no residual current devices (RCDs)

no circuit breakers (MCBs)

no separate circuits

This means:

no protection against residual currents

no protection against defective appliances

no protection against moisture

high risk of electric shock

A 30 mA residual current device (RCD) is now mandatory — especially In

Bathrooms

Kitchens

Outdoor areas

Pool equipment rooms

3. Overloaded circuits

In the 1990s, electricity consumption was low:

No air conditioners

No pool pumps

No electric heaters

No induction cooktops

No photovoltaic systems

Today, circuits are overloaded because:

Too many devices are connected to one circuit

Wiring is too thin

Fuses are too weak or too old

There is no load balancing

Result:

Fuses constantly trip

Wiring gets hot

Outlets short-circuit

Fire hazard increases

Outdated Water Pipes (Plumbing)

Many villas still have:

galvanized or not galvanized steel pipes

copper pipes without protective coating

PVC pipes from the 1990s

outdated pressure reducers

Problems:

Rust → brown water and if steel pipes break you need a complete new instalation

Pitting corrosion → small leaks

Limescale deposits → pressure loss

old PVC pipes → brittle, burst in the heat

poor connections → dripping stains in walls

This is particularly common in La Marina because:

the water is hard (high in calcium)

the pipes were often laid close to the surface

the houses were built quickly

many installations were not carried out according to standards

When modernization is absolutely necessary

Electrical systems must be renewed if:

sockets get warm

fuses frequently trip

1.5 mm² wiring is used

no residual current device (RCD) is installed

air conditioners run through old pipes Running

Pool pumps are running on regular electrical outlets

The fuse box is older than 20 years

The water installation needs to be replaced if:

The water is brown or milky

The pressure fluctuates significantly

The pipes are noisy

There is visible dampness on the walls

Hot water is intermittent

Old steel or PVC pipes are present

Remember the water pipes install 2000 have only 15 years warranty, you can be happy if they still works. But needs to change.

Geben Sie hier den Text...